Specifications- Setting pressure range
- Compound: -100.0~100.0 kPa (-14.50~14.50 psi)
- Vacuum: -101.3~10.0 kPa (-29.9 inHg~1.45 psi)
- Positive: -0.100~1.000 MPa (-14.5~145.0 psi)
- Two switch outputs & One analog output (1~5V)
- Hysteresis adjustable
- High display accuracy: ±0.2% F.S.
- Programmable pressure unit: kPa, MPa, kgf/cm², mmHg, psi, bar, inHg, mmH2O
Specifications
Rated Pressure Range
- Compound -100.0~100.0 kPa (-14.50 psi~14.50 psi)
- Vacuum 101.3~0.0 kPa (-29.9~0.0 inHg)
- Positive 0.000~1.000 MPa (0.0~145.0 psi)
Setting Pressure Range
- Compound -100.0~100.0 kPa (-14.50 psi~14.50 psi)
- Vacuum -101.3~10.0 kPa (-29.9 inHg~1.45 psi)
- Positive -0.100~1.000 MPa (-14.5 psi~145.0 psi)