Accuracy
- ± 0.5 Mbar at 25° C (77° F) - Relative Pressure Accuracy
- ± 0.8° C (± 1.4° F) at 20° C (68° F)
- ± 1.5 Mbar at 25° C (77° F) - Absolute Pressure Accuracy
Ambient Temperature Range
Approvals & Certifications
Communication
- 16-bit - Analog to Digital Converter
Consumption
- 0.5 µA - Current Consumption Into MCLK
Duty Cycle
- 40 to 60 % - Duty Cycle of MCLK
Frequency
- 30 to 500 KiloHertz - External & Serial Data Clock (MCLK & SCLK)
Input
- 0-20 % Vdd - Input & Output Low Voltage
- 80-100 % Vdd - Input & Output High Voltage
Operating Temperature - Sensor
- -40° to 85° C (-40° to 185° F)
Output
- 0.1 µA - Supply Current (Standby or No Conversion)
- 1 mA - Typical Supply Current (During Conversion)
- 4 µA - Typical Supply Current (Average)
Overpressure & Static Pressure Limits
- psi: 145 (kPa: 1,000, bar: 10) - Max.
Pressure Range
- bar: 00.01 to 01.1
- kPa: 01 to 110
- mbar: 10 to 1,100
- psi: 00.145 to 15.95
Resolution
- 0.005° to 0.015° C
- 0.1 Mbar
- 16-bits
Sensor, Probe Type
- Pressure Sensor - Integrated Miniature
Stability
- -1 Mbar Per Year - Long Term Stability
Storage Temperature
- -40° to 85° C (-40° to 185° F)