Accuracy
- ± 1 % of Span - Pressure Non-Linearity
- 0.25 % of Span - Accuracy (Combined Linearity, Hysteresis & Repeatability)
Ambient Temperature Range
Applications
- Corrosive Fluids & Gas Measurement Systems
- Level Controls
- Manifold & barometric Pressure Measurement
- OEM Equipment
- Sealed Systems
- Submersible Depth Monitoring
- Tank Level Measurement
Approvals & Certifications
Compensated Temperature
- 0° to 40° C (32° to 104° F)
Hysteresis
- ± 0.1 % of Span - Pressure Hysteresis
Operating Temperature
- -20° to 85° C (-4° to 185° F)
Output
- 0.5 - 4.5 V - High Level Output
- 0.5 V - Zero Pressure Output (offset)
- 4.5 V - Full Scale Output Span
Pressure Range
- psi: 0 to 150 (kPa: 0 to 1,000, bar: 0 to 10)
Supply Voltage
- 4.75-5.25 V
- 5 Vdc - Typical
Temperature Effect