Ambient Temperature Range
Approvals & Certifications
Communication
- 16-bit - Analog to Digital Converter
- 3-Wire Serial Interface
Consumption
- 0.5 µA - Current Consumption Into MCLK
Duty Cycle
- 40 to 60 % - Duty Cycle of MCLK
Frequency
- 30 to 500 KH - External & Serial Data Clock (MCLK & SCLK)
Input
- 0-20 % Vdd - Input & Output Low Voltage
- 80-100 % Vdd - Input & Output High Voltage
Operating Temperature - Sensor
- -40° to 85° C (-40° to 185° F)
Output
- 0.1 µA at 3 Vdd - Max.
- 1 mA at 3 Vdd - Typical Supply Current (During Conversion)
- 4 µA at 3 Vdd - Typical Supply Current (Average)
Overpressure & Static Pressure Limits
- psi: 725.2 (kPa: 5,000, bar: 50) - Overpressure
Pressure Range
- bar: 0 to 30
- kPa: 0 to 3,000
- psi: 0 to 435.1
Resolution
- 0.005° to 0.015° C
- 16-bits
- 3 Mbar
Response Time
- 35 milliseconds - Conversion Time
Sensor, Probe Type
- Pressure Sensor - Integrated Miniature
Stability
- 50 Mbar Per Year - Long Term Stability
Storage Temperature
- -40° to 85° C (-40° to 185° F)