DP86U-FTG Media Isolated mV Output Pressure Sensor
Brand: American Sensor Technologies IncThe DP86 uncompensated with fitting differential pressure sensor is a double-sided, media compatible, piezoresistive silicon pressure sensor packaged in a 316L stainless steel housing.
The DP86 uncompensated with fitting can be designed with up to 8 different threaded process fittings. The sensing package utilizes silicone oil to transfer pressure from the two 316L stainless steel diaphragms to a single sensing element.
The DP86 uncompensated with fitting is designed for high performance, low pressure applications where differential pressure measurement is required. The stainless steel package makes it suitable for use in liquids and corrosive environments.
Please refer to the DP86, non-silicone oil, constant current and constant voltage (fittings and cable design) for more information on different features of the DP86.
Features- O-Ring Mount/Threaded Process Fittings
- Up to -40°C to +125°C Operating Range
- Up to ±0.1% Pressure Non Linearity
- Solid State Reliability
- Low Pressure
Specifications
Accuracy
- ± 0.1 % of Span Non-Linearity
Ambient Temperature Range
- 25° C (77° F)
Applications
- Corrosive Fluid Systems
- Flow Measurements
- Gas Measurement
- Industrial OEM Equipment
- Level Controls
- Tank Level Measurement
Approvals & Certifications
- RoHS
BSP Connection
- 1/4" BSP Female
- 1/4" BSP Male
Burst Pressure
- psi: 150 to 1,000 (kPa: 1,034 to 6,895, bar: 10.34 to 68.95), whichever is less
Dimensions
- 0.622" x 0.69" (15.82 x 17.52 mm)
Enclosure, Body Material
- 316L Stainless Steel
Hysteresis
- ± 0.05 % of Span - Pressure
- ± 0.25 % of Span - Thermal: Span & Offset
Insulation Resistance
- 50 MΩ at 50 Vdc
Isolation
- 500 Vrms - Voltage Breakdown
Media
- Gas
- Liquids & Gases
NPT Connection
- 1/4" NPT Female
- 1/4" NPT Male
- 1/8" NPT Female
- 1/8" NPT Male
Operating Temperature
- -40° to 125° C (-40° to 257° F)
Output Load
- 5 MΩ
Overpressure & Static Pressure Limits
- psi: 150 to 1,000 (kPa: 1,034 to 6,895, bar: 10.34 to 68.9), whichever is less - Pressure Overload
Power Requirement
- 1.5 mA
Pressure Range
- psid: 0 to 500 (kPa: 0 to 3,447, bar: 0 to 34.47)
Pressure Type
- Differential
Resistance
- 3,800 to 5,800 ohms
Sensitivity
- 13.2-26.5 mV/V at Full Scale
Storage Temperature
- -40° to 125° C (-40° to 257° F)
Supply Voltage
- 5 V
UNF/UNC Connection
- 7/16"-20 UNF Female
- 7/16"-20 UNF Male
Vibration
- 20 G at 10-2000 Hz
- Level Controls
- Tank Level Measurement
- OEM Equipment
- Corrosive Fluids and Gas Measurement Systems
- Flow Measurements